Custom Search
 
  
 
TM 55-1905-223-24-3
Table 2-1. Preventive Maintenance Checks and Services
D-Daily
M-Monthly
Q-Quarterly
A-Annually
B-Biennially
E-Every 1600 Operating Hours
Item
Interval
Items To Be
No.
DM
Q
A
B
E
Inspected/Serviced
Procedures
14
Generator Terminal Box
Check and make sure that no leads are touching to-
continued
gether or grounded against the framework after
cleaning.
15
Engine Oil
Remove the engine oil:
**
a.
Run the engine until it reaches operating
temperature and then shut it off.
b.
Allow time for the oil to settle in the pan.
c.
Drain the oil.
(1)
Open the suction valve in the sump pump
line into the oil pan.
(2)
Manually pump the old oil into the waste
oil tank.
(3)
Close the sump pump valve.
NOTE
Replace the full-flow and bypass
oil filters before adding clean
oil Refer to Item 16.
Add clean oil until the level is at the "H" (high)
mark on the dipstick. Refer to LO 55-1905-223-12
for oil specifications.
Operate the engine and check for oil leaks.
Correct as necessary.
16
Oil Filters (Full-Flow
Change the full-flow and bypass filters.
*
and Bypass)
a.
Remove the full-flow and bypass filters.
* or every 250 operating hours
** or as determined by the Army Oil Analysis Program (AOAP)