Custom Search
 
  
 
TM 55-1905-223-24-5
WARNING
The injector plunger is under spring tension. Do not allow the tool to slip. Personal
injury can result.
(g) Use the rocker lever actuator (1, FIGURE 3-23) to depress the injector plunger three or four
times to make sure all the oil and fuel have been removed from the injector assembly. Allow
the lever to return slowly to prevent damage to the dial indicator.
FIGURE 3-23. Rocker Lever Actuator .
(h) Actuate the lever again, and set the dial indicator at "0" (zero) while holding the injector
plunger to the bottom of its travel.
(i) Slowly release the actuator and check the indicator travel.
(j) The indicator travel should be between 0.226 inch and 0.230 inch. If not within those limits,
go to step (k).
(k) Loosen the locknut on the injector adjusting screw.
(1) Turn the adjusting screw clockwise or counterclockwise to adjust the injector plunger to 0.228 inches.
(m) Hold the adjusting screw in this position. See FIGURE 3-24 . The adjusting screw must not
turn when the lock nut is tightened. Tighten the lock nut to the following value:
- 35 ft-lbs (45 N ) torque.
With adapter
m
- 45 ft-lbs (60 N ) torque.
Without adapter
m
3-37


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business