Custom Search
 
  
 
TM 55-1905-242-14
0022 00
PMCS
Perform all preoperation PMCS for the vessel. Refer to WP 0053 00 and WP 0054 00 for PMCS procedures.
FUEL SYSTEM
WARNING
Fuel vapors are explosive. Fuel is flammable. Before conducting fuel operations, ensure
that firefighting equipment is immediately available for use in case of fire emergency. Do
not smoke or allow smoking or any other open flame in the vicinity of fueling operations.
Wipe clean any fuel spillage and dispose of spilled fuel and fuel-soaked rags in accor-
dance with the appropriate local regulations. A fueling watch supervisor shall be sta-
tioned by the coxswain to ensure compliance with fueling safety procedures. Failure to
comply can result in damaged equipment and serious injury or death to personnel.
Fuel Sounding
Remove the fuel sounding caps and sound both fuel tanks to determine the level of fuel oil. If necessary, replenish the fuel
tanks according to the Fill Fuel Tanks procedure in this work package.
Fill Fuel Tanks
Fill the fuel tanks according to the following procedure:
1.
CLOSE the fuel return valves (8), located in the engine room on bulkhead 39, to ensure that the tanks will be fully
replenished.
2.
Remove the fuel fill cap (9) from the fuel fill pipe.
3.
OPEN the fuel fill valve (10) for the tank to be filled.
10
10
9
11 p/s
8
8
0022 00-3


 


Privacy Statement - Copyright Information. - Contact Us