Custom Search
 
  
 
TM 55-1905-242-14
0022 00
FUEL SYSTEM (continued)
! CAUTION
Do not fill the fuel tank beyond 95 % capacity. Overfilling the fuel tank can cause fuel to
overflow when the fuel expands in the heat of the lazarette.
4.
Fill the fuel tank to 95 % capacity with clean diesel fuel.
5.
CLOSE the fuel fill valve (10).
6.
Secure the fuel sounding cap if not done already.
7.
Repeat steps 3-6 for the other fuel tank, if necessary.
8.
After both tanks are fueled, OPEN the fuel return valves (8) in the engine room.
9.
Secure the fuel fill cap (9).
Fuel Valve Alignment
Align the fuel system valves as follows:
1.
OPEN both fuel supply valves (11) in the lazarette.
2.
OPEN both fuel supply valves (12), both propulsion engine supply valves (13), and the diesel generator supply valve
(14) in the engine room.
3.
Ensure that both return valves (15) are OPEN.
15
15
HYDRAULIC OIL
STORAGE TANK
13
13
12
14
12
0022 00-4


 