Custom Search
 
  
 
TM 55-1905-242-14
0067 00
SERVICE (continued)
6.
Inspect the gaskets that seal the access plates (3). If the gaskets are intact and free of cracks or rot, they may be reused.
If the gaskets are not intact, or if they exhibit cracks and/or rot, procure new gaskets.
7.
Install the gaskets over the access plate (3) openings.
8.
Place the access plates (3) over the openings and secure them in place using the nuts (1) and the washers (2).
9.
Remove the lockouts and tagouts and check the operation of the system.
10. Dispose of the used cleaning solvent and contaminated materials in accordance with local regulations.
3
2
1
END OF WORK PACKAGE
0067 00-2


 


Privacy Statement - Copyright Information. - Contact Us