Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
OPERATOR MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
WASTE OIL TANK, SERVICE
INITIAL SETUP:
Materials/Parts (continued):
Tools and Special Tools:
Goggles, Industrial, No Vents (Item 4, Table 2,
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
Rag, Wiping (Item 5, Table 2, WP 0230 00)
Equipment Condition:
Personnel Required:
Waste oil tank pumped empty
One Watercraft Engineer, 88L
OILY WTR BILGE PUMP circuit breaker secured,
locked out, and tagged out IAW FM 55-502
References:
All oily water collection system valves CLOSED
FM 55-502
TM 55-1905-242-24P (WP 0066)
Materials/Parts:
Cleaning Solvent MIL-PRF-680 (Item 2, Table 2,
Gloves, Chemical Protective (Item 3, Table 2,
SERVICE
WARNING
Cleaning solvent is flammable and its vapor is potentially explosive. Do not use clean-
ing solvent in the vicinity of spark, open flame, or excessive heat. Do not use cleaning
solvent in unventilated spaces. Failure to comply can result in serious injury or death.
Chemical protective gloves and goggles must be worn whenever the waste oil tank
contents may come in contact with the skin or eyes. Prolonged skin contact can cause
illness or injury. Eye contact can cause serious injury. Always wear chemical protective
gloves and goggles when handling cleaning solvent. Failure to comply can cause
serious injury or death.
1.
Remove the nuts (1) and the washers (2) securing each access plate (3).
2.
Remove the access plates (3).
3.
Don chemical protective gloves and goggles.
4.
Using wiping rags, cleaning solvent, scrapers, and wire brush as required, thoroughly clean the inside of the waste oil
tank.
5.
Inspect the interior and exterior of the waste oil tank for cracks, broken welds, or other damage that might compromise the
integrity of the tank. Report any deficiencies to direct support maintenance for repair.
0067 00-1
|
||