INITIAL SETUP:
Personnel Required:
Tools and Special Tools:
Two Watercraft Engineers, 88L
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
References:
FM 55-502
Equipment Condition:
TM 55-1905-242-24P (WP 0070)
Fire pump seacock CLOSED, locked out, and
tagged out IAW FM 55-502
SERVICE
1.
Remove the bolts (1) that secure the cover (2) to the strainer body (3).
2.
Remove the cover (2) and gasket (4).
3.
Remove the strainer screen (5) from the strainer body (3).
4.
Clean the strainer screen (5) using fresh water. It may be necessary to use a wire brush to help remove deposits from the
strainer screen. If the strainer screen cannot be cleaned satisfactorily, replace it.
5.
Inspect the gasket (4). Replace the gasket if it is broken or shows signs of cracking or deterioration.
6.
Install the strainer screen (5) into the strainer body (3).
7.
Install the gasket (4) into its recess in the strainer body (3).
8.
Install the cover (2) onto the strainer body (3) and secure it with the bolts (1).
9.
Remove the lockouts and tagouts, OPEN the fire pump seacock, and check for leaks.
1
5
3
4
2
1
END OF WORK PACKAGE