Custom Search
 
  
 
TM 55-1905-242-14
OPERATOR MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
FIRE PUMP, SERVICE
INITIAL SETUP:
Personnel Required:
Tools and Special Tools:
One Watercraft Engineer, 88L
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
Materials/Parts:
Equipment Condition:
Grease (Item 21, Table 2, WP 0230 00)
Fire pump engaged and pumping
References:
Fire monitor discharging over side
TM 55-1905-242-24P (WP 0070)
SERVICE
WARNING
Ensure that all personnel are clear of rotating components. Use extreme caution when
working around rotating components. Do not allow hands or tools to come in contact
with rotating components. Do not wear loose clothing, jewelry, or anything else that
might become entangled in rotating components. Failure to comply can result in dam-
aged equipment and serious injury or death to personnel.
1.
Remove the pump drive shaft shield.
2.
Apply 2 to 3 shots of grease to the grease fittings (1) on the input and output shafts. Each shaft has a single grease
fitting.
2
3
270
87
1
0069 00-1


 