3.
Check for water leakage at the input and output shafts. Normal leakage is 3 to 4 drops per minute. If leakage exceeds this
rate, adjust the shaft packing as follows:
a.
If leakage exceeds the normal rate, evenly tighten the adjusting nuts (2) until the leakage rate is reduced to normal
levels.
b.
If leakage is lower than the normal rate, evenly loosen the adjusting nuts (2) while gently tapping the gland (3) with
a hammer until the leakage rate increases to normal levels.
c.
If normal leakage levels cannot be obtained, notify direct support maintenance for repair.