Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
OPERATOR MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
FIRE MONITOR, ADJUST/SERVICE
INITIAL SETUP:
Materials/Parts:
Tools and Special Tools:
Compound, Antiseize ( Item 12, Table 2, WP 0230 00)
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
References:
FM 55-502
Equipment Condition:
FIRE PUMP CLUTCH circuit breaker set to OFF,
locked out, and tagged out IAW FM 55-502
Personnel Required:
Two Watercraft Engineers, 88L
ADJUST
1.
Tighten the fire monitor fixing screws (1) snugly enough to prevent the fire monitor from moving easily.
2.
Remove the lockouts and tagouts and check the operation of the system.
SERVICE
1.
Remove the fire monitor fixing screws (1) from the fire monitor swivel joints (2).
2.
Use a wire brush to clean any corrosion or deposits from the fire monitor fixing screw (1) threads.
3.
Coat the fire monitor fixing screw (1) threads with a light coating of antiseize compound.
! CAUTION
Do not overtighten the fire monitor fixing screws. Overtightening of the screws can
cause damage to the fire monitor swivel joints.
4.
Install the fire monitor fixing screws (1) into the fire monitor swivel joints (2) and adjust the fire monitor.
1
2
END OF WORK PACKAGE
0070 00-1/2 blank
|
||