Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
RAW WATER SYSTEM PIPING, HOSES, AND VALVES, REPLACE/REPAIR
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine (Item 1,
Two Watercraft Engineers, 88L
Table 1, WP 0230 00)
Wrench, Pipe, Adj Heavy Duty (Item 30, Table 1,
Materials/Parts:
Sealant (Tape, Antiseizing) (Item 14, Table 2, WP 0230 00)
Flange Gasket (p/n 76-00317, qty 2)
Equipment Condition:
Seacock for applicable system CLOSED, locked
References:
out, and tagged out IAW FM 55-502
FM 55-502
TM 55-1905-242-24P (WP 0048)
REMOV L
A
WARNING
The seacock for the affected system must be closed before beginning replacement of
any raw water system piping, hoses, and/or valves. Failure to observe this warning can
result in flooding of the space, damage to the vessel, and serious injury or death to
personnel.
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
0127 00-1
|
||