Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0127 00
REMOVAL (continued)
4
5
4
8
6
8
8
6
6
8
8
8
6
1
7
2
3
9
6
4
5
4
1.
Remove the bolts (1) and lockwashers (2) that secure the flange (3) to its mounting. After removing flange, save old
gasket to use as a template for creating new gasket.
2.
Loosen the hose clamps (4) that secure the hoses (5) to the piping (6).
3.
Remove the smallest possible piping section containing the pipe, hose, or valve that must be replaced.
4.
Unscrew the piping (6) from the valve (7) or fitting (8) as required.
INSTALLATION
1.
Procure new pipe, valves, hoses, or fittings as required.
2.
If piping (6) was removed from a valve (7) or fitting (8) during Removal, wrap the male pipe threads with antiseizing tape
sealant prior to installation.
3.
Screw the piping (6) into the valve (7) or fitting (8).
4.
Install the piping section containing the pipe, hose, or valve that was replaced, back into the system.
5.
Tighten the hose clamps (4) that secure the hoses (5) to the piping (6).
6.
Place a new gasket (9) on the flange mounting and position the flange (3) for installation.
7.
Install the bolts (1) and lockwashers (2) that secure the flange (3) to its mounting.
8.
Remove the lockouts and tagouts, check the operation the system, and check for leakage.
END OF WORK PACKAGE
0127 00-2
|
||