Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
RAW WATER SYSTEM DUPLEX STRAINER, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
Two Watercraft Engineers, 88L
(Item 1, Table 1, WP 0230 00)
Materials/Parts:
Equipment Condition:
Sealant (Tape, Antiseizing) (Item 14, Table 2, WP 0230 00)
Seacock CLOSED, locked out, and tagged
out IAW FM 55-502
References:
FM 55-502
TM 55-1905-242-24P (WP 0049)
REMOVAL
WARNING
The seacock for the affected system must be closed before beginning replacement of
the raw water system strainer. Failure to observe this warning can result in flooding of
the space, resulting in damage to the vessel and serious injury or death to personnel.
1.
Remove the drain plug (1) to drain the selected strainer (2).
4
8
2
3
9
6
8
11
7
10
12
1
5
0128 00-1


 