TM 55-1905-242-14
0128 00
REMOVAL (continued)
2.
Rotate the selector handle (3) to select the remaining strainer (4) and drain that strainer.
3.
Loosen the hose clamps (5) and slide them back off the hose (6).
4.
Remove the hose (6).
5.
Using two wrenches, disconnect the union fitting (7).
6.
Remove the four bolts (8) that secure the strainer assembly (9) to the bulkhead.
7.
Remove the strainer assembly (9) with the associated piping attached.
8.
Remove the pipes (10 and 11) from the strainer assembly (9).
INSTALLATION
1.
Wrap the male pipe threads with antiseizing tape sealant and install the pipes (10 and 11) on the strainer assembly (9).
2.
Position the strainer assembly (9) on the bulkhead and secure it with the four bolts (8).
3.
Slide the hose (6) over the ends of the pipes (10 and 12).
4.
Secure the hose (6) with the hose clamps (5).
5.
Connect and securely tighten the union fitting (7).
6.
Install the drain plug (1) and position the selector handle (3) to select one of the strainers (2 or 4).
7.
Remove the lockouts and tagouts, operate the system, and check for leakage.
8.
After checking for leakage with one strainer (2 or 4) selected, position the selector handle (3) to select the remaining
strainer and check it for leakage.
END OF WORK PACKAGE