Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
POTABLE WATER SYSTEM PIPING, HOSES, AND VALVES, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
Two Watercraft Engineers, 88L
(Item 1, Table 1, WP 0230 00)
Crowfoot Attachment, Socket Wrench, 11/4
References:
(Item 31, Table 1, WP 0230 00)
FM 55-502
Suitable Drain Pan
TM 55-1905-242-24P (WP 0050)
Equipment Condition:
FRESH WTR TANK PRESS SET circuit
breaker set to OFF, locked out, and
tagged out IAW FM 55-502
REMOVAL
1.
Position a suitable drain pan under the faucet to be replaced.
2.
Turn ON the faucet (both hot and cold) and ensure that no water runs. If no water runs, proceed to the next step. If water
runs, allow time for the residual pressure in the pressure set to dissipate. If water continues to run, check to ensure that
the circuit breaker is properly secured.
3.
Loosen and remove the hose fittings (1) from the standing piping.
4.
Loosen and remove the nut (2) that secures the faucet assembly (3) to the sink.
5.
Remove the faucet assembly (3) from the sink.
0129 00-1


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business