TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
WASTE OIL PUMP, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
Two Watercraft Engineers, 88L
(Item 1, Table 1, WP 0230 00)
Multimeter (Item 2, Table 1, WP 0230 00)
References:
FM 55-502
Equipment Condition:
TM 55-1905-242-24P (WP 0067)
OILY WTR BILGE PUMP circuit breaker set to
OFF, locked out, and tagged out
IAW FM 55-502
All oily water collection system valves CLOSED
REMOVAL
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Set the multimeter to the Vdc (Volts direct current) setting. Place one multimeter lead on each of the two motor terminals
(1). If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the circuit breaker is properly
secured.
2.
Disconnect the hoses (2) from the waste oil pump (3).
3.
Label and disconnect the wiring (4) from the two motor terminals (1).
0142 00-1


 