Tweet |
Custom Search
|
|
|
||
TM 55-1925-273-10-1
0069 00
3
2
5
4
(PUSH BUTTON
FACES STBD)
1
AFT
Figure 12. Ship's Service Diesel Generator Controls
! CAUTION
If the engine fails to start within 30 seconds, release the START switch, and wait two minutes to
allow the starter motor to cool before attempting to start the engine again.
NOTE
Prolonged cranking at low oil pressure can activate the mechanical safety shut off. If the reset
lever is in the shutoff position, reset the mechanical shut off control.
d.
Monitor the engine's speed on the CRT display in the EOS.
e.
Allow the engine to operate in a no-load condition for 3 to 5 minutes or until the water temperature gauge (figure
12, item 5) begins to rise.
f.
During normal operation, ensure the engine gauges read in the NORMAL range.
4.
Load the diesel (bringing the generator on-line).
a.
Ensure the following prior to loading the diesel:
(1)
The engine is at proper operating speed for 3-5 minutes.
(2)
All engine gauges are in the normal range.
(3)
The engine is warmed up.
0069 00-8
|
||