TM 55-1905-242-14
DIRECT SUPPORT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
RAMP LOCKING HYDRAULIC CYLINDERS, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Materials/Parts:
Tool Kit, Mechanic's Rail and Marine (Item 1,
Table 1, WP 0230 00)
Hydraulic Fluid (Item 1, Table 2, WP 0230 00)
Suitable Drain Pan
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Goggles, Industrial, No Vents (Item 4, Table 2,
Equipment Condition:
Propulsion engines secured, locked out, and
References:
tagged out IAW FM 55-502
Bow ramp lowered
FM 55-502
TM 55-1905-242-24P (WP 0093)
Personnel Required:
One Watercraft Engineer, 88L
REMOVAL
WARNING
Do not allow hydraulic fluid or cleaning solvent to come in contact with unprotected
skin or eyes. Prolonged skin contact can cause illness or injury. Eye contact can cause
serious injury. Always wear chemical protective gloves and goggles when handling
used hydraulic fluid and cleaning solvent. Failure to comply can result in illness, seri-
ous injury, or death.
Hydraulic hoses and lines may be under pressure. Relieve pressure by operating the
appropriate control valve if possible. Loosen fittings on hose lines slowly. Allow oil to
run around threads of fitting, releasing pressure before disconnecting fitting. Releasing
pressurized oil suddenly can cause serious injury or death.
1.
Don chemical protective gloves and goggles.
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
2.
Remove the bolts (1) that secure the protective cover (2) to the cargo well. Remove the protective cover.
3.
Position a suitable drain pan beneath the work area.
4.
Loosen, but do not remove, the hydraulic line (3) at the elbow (4) to permit any residual hydraulic pressure or fluid to
drain from the system.
0189 00-1
|
||