Figure 5-13. Keel Valve Parts to be serviced.
Keel Valve Cleaning Procedures.

Maintenance Manual For F-530 Inflatable Assault Boat Model F-530 Iab Model F-530-Iab \(Nsn 1940-01-445-9692\) Page Navigation
  67    68    69    70    71  72  73    74    75    76    77  
img
. .
TM 5-1940-321-13&P
Figure 5-14. Removing Ring-shaped Flat Neoprene Valve Insert Gasket form Metal Valve Insert.
Figure 5-15. Inspecting Ring-shaped Flat Neoprene Valve Insert Gasket for Cuts and Cracks.
Using caution when working with toluene. Toluene is a flammable and poisonous
solvent. Do not use near sparks or flame. Use outdoors or provide adequate
ventilation. Use in a confined space can cause loss of consciousness and in
extreme concentrations, death. Wipe up all spills immediately. Remove toluene
soaked towels from the work area to reduce the concentration of toluene in the air
and prevent fire. Minimize contact of toluene with the skin. Never leave toluene
soaked towels on boat fabric.
5-26