• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Buoyancy Tube Pressure Check.
Keel Pressure Check.

Maintenance Manual For F-530 Inflatable Assault Boat Model F-530 Iab Model F-530-Iab \(Nsn 1940-01-445-9692\) Page Navigation
  46    47    48    49    50  51  52    53    54    55    56  
img
. . . . . . . . . . . . .
TM 5-1940-321-13&P
Table 5-1. Scheduled Maintenance Action Index.
Interval
Maintenance Category Maintenance Action
Paragraph Reference
Check pressure of buoyancy tubes and
DR
Unit
5-7
keel.
Check tightness of outboard engine
DR
Unit
5-8
mounting clap screws.
Check tightness of through transom
DR
Unit
5-9
outboard engine mountin bolts.
DR
Unit
Check tightness of transom straps.
5-10
Clean craft, flush dirt and sand from
under flooring and from between skirt
VR
Unit
5-11
and lower buoyancy tubes.
Clean craft, remove flooring, remove
MR
Unit
5-12
dirt and sand under flooring.
S
Unit
Perform pressure retention test.
5-19
Clean, inspect, and lubricate
S
Direct
5-13
intercommunicating valves.
S
Direct
Clean and inspect keel valve.
5-14
Paint transom, paddles, and
A
Direct
5-15
thrustboard.
Inspect and CO2 one-way diffuser
S
Unit
5-16
valve.
D Daily during periods of craft use.
V After each use of the craft.
M Monthly during periods of craft operation.
S Semiannually.
A Annually
R As specified in procedures.
NOTE: Correct pressure buoyancy tubes is 240-280 mb (3.5-4.1 psi). Correct pressure for the keel
is 220-240 mb (3.2-3.5 psi).
5-5